MEB 590 Battery Pack Design: 400 V and 800 V Systems
Short answer: A 2P8S MEB 590 module has a nominal voltage of 29.36 V. Fourteen modules in series produce approximately 411 V nominal, suitable for a 400 V system architecture. Twenty-eight modules in series produce approximately 822 V nominal, suitable for an 800 V architecture. Series count is set by the inverter voltage window; additional capacity comes from parallel strings.
Pack voltage in a battery-electric or stationary system is not a free variable. It is set by the inverter or power-conversion stage, which specifies a minimum and maximum DC bus voltage. The module count in series follows from that window, and additional energy capacity is added by connecting strings in parallel. This article works through both common targets, 400 V and 800 V, using a single reference module and showing each calculation step.
The reference module
The MEB 590 module specifications for the 2P8S configuration used throughout this article are as follows.
| Parameter | Value |
|---|---|
| Configuration | 2P8S |
| Nominal voltage | 29.36 V |
| Voltage window | 22.4 V to 34.8 V |
| Capacity | 227 Ah |
| Energy (gross) | 6.66 kWh |
| Mass | 31.4 kg |
| Dimensions (L x W x H) | 590 x 225 x 110 mm |
| Continuous current at 1C | 227 A |
| Cycle life at 80 % DoD | 1,200 cycles |
All figures are taken directly from the catalogue datasheet. Any parameter not listed here, such as peak current duration or thermal limits, should be taken from the same datasheet rather than assumed.
Why the inverter sets the series count
A traction or storage inverter accepts a DC bus voltage within a defined window. Operating outside that window, either too low during discharge or too high during charge, will cause the inverter to fault or to derate. The pack designer therefore works backward: take the inverter's minimum and maximum DC input voltage, divide each by the module's corresponding cell-level voltage limits, and the result is the allowable range of series modules.
For a nominal target, dividing the target bus voltage by the module's nominal voltage gives a first approximation of the series count. The voltage window of the resulting string must then be verified to sit within the inverter's acceptance range.
More capacity is never added by increasing the series count beyond what the voltage window allows. It is added by connecting complete strings in parallel, which keeps the voltage identical and multiplies the amp-hour capacity.
400 V system: 14 modules in series
Series count calculation: 400 V target divided by 29.36 V per module equals 13.6, rounded to 14 modules.
Resulting string parameters:
| Parameter | Calculation | Result |
|---|---|---|
| Nominal voltage | 14 x 29.36 V | 411 V |
| Minimum voltage | 14 x 22.4 V | 314 V |
| Maximum voltage | 14 x 34.8 V | 487 V |
| Gross energy | 14 x 6.66 kWh | 93 kWh |
| Mass | 14 x 31.4 kg | 440 kg |
| Continuous current at 1C | 227 A (string current) | 227 A |
| Continuous power at 1C | 227 A x 411 V | approx. 93 kW |
The voltage window of 314 V to 487 V is what the inverter must accept across the full state-of-charge range. Confirm this against the inverter datasheet before finalising the series count.
The 93 kWh figure is gross energy. Usable energy depends on the state-of-charge window the BMS applies. At 80 % depth of discharge, as stated for the 1,200-cycle rating, usable energy is approximately 74 kWh per string.
800 V system: 28 modules in series
Series count calculation: 800 V target divided by 29.36 V per module equals 27.3, rounded to 28 modules.
Resulting string parameters:
| Parameter | Calculation | Result |
|---|---|---|
| Nominal voltage | 28 x 29.36 V | 822 V |
| Minimum voltage | 28 x 22.4 V | 627 V |
| Maximum voltage | 28 x 34.8 V | 974 V |
| Gross energy | 28 x 6.66 kWh | 187 kWh |
| Mass | 28 x 31.4 kg | 879 kg |
| Continuous current at 1C | 227 A (string current) | 227 A |
| Continuous power at 1C | 227 A x 822 V | approx. 187 kW |
The maximum voltage at full charge, 974 V, is relevant for component insulation ratings, cabling specifications and safety interlock design. High-voltage systems above 800 V nominal require particular attention to creepage and clearance distances under standards such as IEC 62619, which covers safety requirements for secondary lithium cells and batteries used in stationary applications.
Adding capacity with parallel strings
Once the series count is fixed by the voltage target, capacity scales linearly with the number of parallel strings.
| Strings in parallel | Nominal voltage | Gross energy | Mass |
|---|---|---|---|
| 1 (14S) | 411 V | 93 kWh | 440 kg |
| 2 (14S x 2P) | 411 V | 186 kWh | 880 kg |
| 3 (14S x 3P) | 411 V | 279 kWh | 1,320 kg |
| 1 (28S) | 822 V | 187 kWh | 879 kg |
| 2 (28S x 2P) | 822 V | 374 kWh | 1,758 kg |
Parallel strings raise additional engineering requirements. Current sharing between strings must be managed, because even small differences in state of charge or internal resistance between strings will drive circulating currents. Common approaches include passive balancing through matched string impedance, active string isolation using contactors per string, and BMS architectures that monitor each string independently. The appropriate approach depends on the application and the BMS specification, which should be established per project rather than assumed from the module specification alone.
For stationary storage applications, the MEB 590 module in energy storage systems article covers the broader context of using this format in grid-connected and behind-the-meter installations.
Format comparison: MEB 590 versus VDA 355
Engineers selecting a module format for a new pack design often compare the MEB 590 against the VDA 355. The table below summarises the key dimensional and electrical differences using the 2P8S MEB 590 reference and a representative VDA 355 configuration. VDA 355 figures vary by configuration; consult the relevant datasheet for the specific variant.
| Parameter | MEB 590 (2P8S) | VDA 355 (typical 2P6S) |
|---|---|---|
| Length | 590 mm | 355 mm |
| Nominal voltage | 29.36 V | approx. 22 V |
| Capacity | 227 Ah | varies by cell |
| Energy per module | 6.66 kWh | approx. 2 to 4 kWh |
| Primary application | Vehicle traction, stationary storage | Vehicle traction |
The MEB 590's larger cell count per module means fewer modules are needed to reach a given pack voltage and energy target, which can simplify busbar routing and reduce the number of inter-module connections. The 590 format overview covers the mechanical standardisation in more detail.
The EU Battery Regulation 2023/1542, published on EUR-Lex, introduces traceability and performance declaration requirements that apply to batteries placed on the European market. Pack designers working with MEB 590 modules should account for these documentation requirements early in the design process.
Frequently asked questions
How many MEB 590 modules in series for a 400 V battery pack?
Using the 2P8S reference module at 29.36 V nominal, 14 modules in series give approximately 411 V nominal with a voltage window of 314 V to 487 V. This is the series count to target for a nominal 400 V system architecture, subject to verification against the inverter's DC input specification.
How many MEB 590 modules in series for an 800 V battery pack?
Twenty-eight modules in series give approximately 822 V nominal with a voltage window of 627 V to 974 V. The 974 V maximum at full charge must be within the insulation and component ratings of all pack elements, including cabling, contactors and the inverter DC input.
What is the gross energy of a 14-module MEB 590 string?
Fourteen 2P8S modules each rated at 6.66 kWh give 93 kWh gross per string. Usable energy at 80 % depth of discharge is approximately 74 kWh. The cycle life rating of 1,200 cycles is stated at 80 % DoD, so that figure should be used as the sizing basis.
How is additional capacity added without changing pack voltage?
Capacity is added by connecting complete strings in parallel. Each additional parallel string multiplies amp-hour capacity and gross energy while keeping nominal voltage unchanged. Parallel strings require current-sharing management and, typically, independent string monitoring within the BMS architecture.
Does module series count alone determine pack power?
No. Continuous power is the product of string current and string voltage. At 1C the reference module delivers 227 A. A 14-module string at 411 V nominal gives approximately 93 kW continuous; a 28-module string at 822 V gives approximately 187 kW. Higher power requires either a higher C-rate, confirmed from the datasheet, or additional parallel strings.
Specify your pack
For detailed module specifications and to discuss series or parallel configurations for your application, review the MEB 590 modules available from Avantis Energy or contact the technical team directly.